1.
International Journal of Arrhythmia ; : 12-2022.
Article in English | WPRIM | ID: wpr-937688

ABSTRACT

Background@#The efficacy and safety of high-power, short-duration (HPSD) radiofrequency catheter ablation for atrial fibrillation (AF) have been demonstrated in several studies. We aimed to evaluate and compare the effects of the conventional method and the HPSD method for AF ablation on the sinus and AV node function in patients with paroxysmal AF. @*Methods@#The medical records of patients with paroxysmal AF who underwent pulmonary vein isolation (PVI) were retrieved from a prospectively collected AF ablation registry at a large-sized tertiary center. The HPSD group (n = 41) was distinguished from the conventional ablation group (n = 198) in terms of the power (50 W vs. 20–40 W) and dura‑ tion (6–10 s vs. 20–30 s) of radiofrequency energy delivery during PVI. Peri-procedural changes in cardiac autonomy were assessed in terms of the changes in sinus cycle length (SCL), block cycle length (BCL), and effective refractory period (ERP) of the atrioventricular node (AVN). @*Results@#The SCL, BCL, and ERP of the AVN at baseline and post-ablation were not significantly different between the conventional ablation group and the HPSD group. Shortening of the SCL, BCL, and ERP of the AVN was observed immediately after AF ablation in both groups. One-year recurrence of AF/atrial flutter (35.1% vs. 20.3%; P = 0.011) and atrial flutter (13.8% vs. 4.7%; P = 0.015) were higher in the HPSD group than in the conventional ablation group. @*Conclusion@#Both the HPSD and the conventional ablation method resulted in post-ablation vagal modification as evidenced by the shortening of SCL, BCL, and ERP of the AVN. One-year recurrence of atrial flutter and AF/atrial flutter was higher in patients who underwent the HPSD method.

2.
Korean Circulation Journal ; : 143-153, 2021.
Article in English | WPRIM | ID: wpr-893900

ABSTRACT

Background and Objectives@#Data regarding the safety of atrial fibrillation (AF) ablation using high-power (50 W) radiofrequency (RF) energy in Asian populations are limited. This study was conducted to evaluate the incidence and pattern of esophageal injury after highpower AF ablation in an Asian cohort. @*Methods@#We searched the prospective AF ablation registry to identify patients who underwent AF ablation with 50 W RF energy using the smart touch surround flow catheter (Biosense Webster, Diamond Bar, CA, USA). Visitag™ (Biosense Webster) was used for lesion annotation with predefined settings of catheter stability (3 mm for 5 seconds) and minimum contact force (50% of time >5 g). All patients underwent upper gastrointestinal endoscopy at 1 or 3 days after the ablation. @*Results@#A total of 159 patients (mean age: 63±9 years, male: 69%, paroxysmal AF: 45.3%, persistent AF: 27.7%, long-standing persistent AF: 27.0%) were analyzed. Initially, 26 patients underwent pulmonary vein isolation with 50 W for 5 seconds at each point. The remaining 133 patients underwent prolonged RF duration (anterior 10 seconds and posterior 6 seconds). The incidence rates of esophageal erythema/erosion and superficial ulceration were 1.3% for each type of the lesion. Food stasis, a suggestive finding of gastroparesis, was observed in 25 (15.7%) patients. There were no cases of cardiac tamponade, stroke, or death. @*Conclusions@#In Asian patients, AF ablations using 50 W resulted in very low rates of mild esophageal complications.

3.
Korean Circulation Journal ; : 143-153, 2021.
Article in English | WPRIM | ID: wpr-901604

ABSTRACT

Background and Objectives@#Data regarding the safety of atrial fibrillation (AF) ablation using high-power (50 W) radiofrequency (RF) energy in Asian populations are limited. This study was conducted to evaluate the incidence and pattern of esophageal injury after highpower AF ablation in an Asian cohort. @*Methods@#We searched the prospective AF ablation registry to identify patients who underwent AF ablation with 50 W RF energy using the smart touch surround flow catheter (Biosense Webster, Diamond Bar, CA, USA). Visitag™ (Biosense Webster) was used for lesion annotation with predefined settings of catheter stability (3 mm for 5 seconds) and minimum contact force (50% of time >5 g). All patients underwent upper gastrointestinal endoscopy at 1 or 3 days after the ablation. @*Results@#A total of 159 patients (mean age: 63±9 years, male: 69%, paroxysmal AF: 45.3%, persistent AF: 27.7%, long-standing persistent AF: 27.0%) were analyzed. Initially, 26 patients underwent pulmonary vein isolation with 50 W for 5 seconds at each point. The remaining 133 patients underwent prolonged RF duration (anterior 10 seconds and posterior 6 seconds). The incidence rates of esophageal erythema/erosion and superficial ulceration were 1.3% for each type of the lesion. Food stasis, a suggestive finding of gastroparesis, was observed in 25 (15.7%) patients. There were no cases of cardiac tamponade, stroke, or death. @*Conclusions@#In Asian patients, AF ablations using 50 W resulted in very low rates of mild esophageal complications.

4.
International Journal of Arrhythmia ; : e13-2020.
Article | WPRIM | ID: wpr-835475

ABSTRACT

Background@#An automated tagging module (VISITAG™; Biosense Webster, Irvine, CA) allows objective demonstration of energy delivery. However, the effect of VISITAG™ on clinical outcomes remains unclear. This study evaluated (1) clinical outcome after AF ablation using VISITAG™ and (2) the prevalence of gaps in the ablation line. @*Methods@#This retrospective analysis included 157 consecutive patients (mean age, 56.7 years; 73.2% men) with paroxysmal atrial fibrillation who underwent successful PVI between 2013 and 2016. Outcomes after the index procedure were compared between those using the VISITAG™ module (VISITAG group, n = 62) and those not using it (control group, n = 95). The primary outcome was recurrence of AF or atrial tachycardia after a blanking period of 3 months. @*Results@#The VISITAG group showed significantly shorter overall procedure time (172.2 ± 37.6 min vs. 286.9 ± 66.7 min, P  15 s,  60% force over time, > 6 g contact force) showed higher recurrence-free survival rate compared with those with gaps (borderline statistical significance, 91.7% vs. 66.0%, P = 0.094). @*Conclusion@#Use of the VISITAG™ module significantly reduced procedure, ablation, and fluoroscopic times with a similar AF/AT recurrence rate compared with the conventional ablation. Clinical implications of minimizing gaps along the ablation line should be evaluated further in the future prospective studies.